3 - 39
The factory defaults for the Output A Control Parameters are found in Table 3-32. To
modify the default parameters refer to Table 3-33. If you are uncertain how to enter a
Control Parameter, review the
Operations: Keypad
section.
Table 3-34 Default Control Parameters for Output A
CP Parameter Name Parameter Value
CP-90 Output A Segment 1
CP-91 Output A Direction 0
CP-92 Output A Polarity 0
Table 3-35 Entering Output A Control Parameters
CP Parameter Name Parameter Value
CP-90 Output A Segment Enter “1” to activate Output A during the constant pitch
plateau segment of the Follower profile.
Enter “2” to activate Output A during the constant pitch
plateau and Accel/Decel segment of the Follower profile.
Enter “3” to activate Output A during the Dwell
segment of the Follower profile.
CP-91 Output A Direction Enter “1” to activate Output A during the forward
direction.
Enter “2” to activate Output A during the reverse
direction.
Enter “3” to activate Output A during the forward and
reverse directions.
CP-92 Output A Polarity Enter “0” to activate Output A as Active Low Voltage
Level.
Enter “1” to activate Output A as Active High Voltage
Level.