MV-57 DISCRETE OUTPUTS - GROUP B
The Discrete Outputs - Group B displays the status of the Output B discrete outputs. The
number “1” indicates an inactive or de-energized (logic high) level. The number “0” indicates an
active or energized (logic low) level. In the example below, “Output B” is the inactive or de-
energized (logic high) level.
Output B
Not Used
Not Used
Not Used
Not Used
Not Used
MV-58 INVALID PROFILE
If a profile entry has been rejected, the Invalid Profile parameter will display the reason that it
was rejected. The M-Traverse will not allow your system to enter "Run" if there is an invalid
profile. The digit that displays a number “1” is the error. In the example below, “The process
length is zero or negative” is the error.
Lead Size or Follower Size > 14,400,000
Process length is either zero or negative
Not Used
Not Used
Not Used
Not Used