5 - 36
APPENDIX D: CONTROL PARAMETER
REFERENCE
USER
CODE DESCRIPTION MIN MAX DEFAULT RECORD UNITS
CP-01 Setpoint 1 000.000 999999 0.000 E.U.
CP-02 Traverse Length 1 000.000 999999 0.000 E.U.
CP-03 Setpoint 2 000.000 999999 0.000 E.U.
CP-04 Traverse Length 2 000.000 999999 0.000 E.U.
CP-05 Setpoint 3 000.000 999999 0.000 E.U.
CP-06 Traverse Length 3 000.000 999999 0.000 E.U.
CP-07 Setpoint 4 000.000 999999 0.000 E.U.
CP-08 Traverse Length 4 000.000 999999 0.000 E.U.
CP-09 Accel/Decel Length 0 65535 0 Lead Lines
CP-10 Dwell 0 65535 0 Lead Lines
CP-14 Control Mode 1 3 1 Coded
CP-15 Engineering Units 000.000 999999 0.000 E.U.
CP-16 Lead PPR Reel 0 999999 1000 Lead Lines
CP-17 Foll Lines per EU. 0 999999 1000 Lines/EU
CP-18 PPR-Follower 60 6000 60 PPR
CP-19 Max RPM - Follower 100 30000 2000 RPM
CP-23 High Speed Alarm 0 30000 2000 RPM
CP-24 Edge/Ctr Based Profile 1 2 1 Coded
CP-25 Change Activation 1 3 1 Coded
CP-26 Batch Format 1 2 1 Coded
CP-27 Batch Limit 0 9999 0 Counts
CP-28 Batch Preact Distance 000.000 999999 999999 E.U.
CP-29 Unipolar/Bipolar 1 2 2 Coded
CP-30 At-Home Band 1 60000 4 Foll Lines
CP-31 Home Offset -99999 999999 0 E.U.
CP-32 Resume Enable 1 3 1 Coded
CP-35 Home Sync Polarity 1 2 1 Coded
CP-36 Fwd/Rev Limit Polarity 1 2 2 Coded
CP-37 Forward Limit Format 1 2 1 Coded
CP-60 Accel/Decel 0.1 600.0 5.0 Seconds