The factory defaults for the Batch Control Parameters are found in Table 3-26. To
modify the default parameters refer to Table 3-27. If you are uncertain how to enter a
Control Parameter, review the
Operations: Keypad
section.
Table 3-28 Default Batch Control Parameters
CP Parameter Name Parameter Value
CP-26 Batch Format 1
CP-27 Batch Limit 0
CP-28 Batch PreAct Distance 999999
Table 3-29 Entering Batch Control Parameters
CP Parameter Name Parameter Value
CP-26 Batch Format Enter “1” in CP-26 for Follower traverses.
Enter “2” in CP-26 for Lead reel revolutions.
CP-27 Batch Limit Enter the total number of Follower traverses or Lead
reel revolutions that you want counted.
CP-28 Batch PreAct Dist Enter a specific preact distance at which to activate the
Batch Done (only if CP-26 is set at “1”).