5 - 34
CP-90 OUTPUT A SEGMENT
Use the Output A Segment (CP-90) parameter to determine what segment of the Follower profile
will activate Output A.
Enter “1” in CP-90 to activate Output A during the constant pitch plateau
segment of the Follower profile.
Enter “2” in CP-90 to activate Output A during the constant pitch plateau and
Accel/Decel segments of the Follower profile.
Enter “3” in CP-90 to activate Output A during the dwell segment of the
Follower profile.
The diagram below illustrates the segments of the Follower profile :
Constant
Pitch
Plateau
Follower Profile
Accel/Decel
Accel/Decel
Dwell
1
2
3
CP-91 OUTPUT A DIRECTION
Use the Output A Direction (CP-91) parameter to specify the direction in which Output A will
operate.
Enter “1” in CP-91 to activate Output A during the forward direction.
Enter “2” in CP-91 to activate Output A during the reverse direction.
Enter “3” in CP-91 to activate Output A during the forward and reverse
directions.
CP-92 OUTPUT A POLARITY
Use the Output A Polarity (CP-92) parameter to specify the voltage polarity at which Output A will
operate.
Enter “0” in CP-92 to activate Output A as Active Low Voltage Level.
Enter “1” in CP-92 to activate Output A as Active High Voltage Level.