Contrex MLP-Trim Manual de usuario Pagina 54

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 216
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 53
3 - 14
Table 3-9 Entering Master Scaling Analog Feedback Parameters
CP Parameter Name Parameter Value
CP-84 Analog Input Allocation
CP-20 Master Engineering Units
Enter a value of "2" to allocate the
analog input as the feedback source.
Enter the Master Engineering Unit
value for an analog feedback level of
10.0 volts.
Note: The Max RPM Feedback (CP-34) and PPR Feedback (CP-31) control
parameters, used for scaling Master mode with frequency feedback, are
ignored when using analog feedback scaling.
Vista de pagina 53
1 2 ... 49 50 51 52 53 54 55 56 57 58 59 ... 215 216

Comentarios a estos manuales

Sin comentarios