MP-54 LOGIC INPUTS - GROUP A
The Logic Inputs A displays the status of the Run, Jog, R–Stop and F–Stop digital
inputs. The number “1” indicates an open, or logic high level. The number “0” indicates
a closed, or logic low level (shorted to common). In the example below, “Jog” is the
open or logic high level.
Run (J6 Pin 4)
Jog (J6 Pin 5)
R–Stop (J6 Pin 6)
F–Stop (J6 Pin 7)
Code
MP-55 LOGIC INPUTS - GROUP B
The Logic Inputs B displays the status of the Master/Follower, Setpoint Select, Scroll
Up and Scroll Down digital inputs. The number “1” indicates an open, or logic high level.
The number “0” indicates a closed, or logic low level (shorted to common). In the
example below, “Setpoint Select” is the open or logic high level.
Master or Follower (J6 Pin 9)
Setpoint Select (J6 Pin 10)
Scroll Up (J6 Pin 11)
Scroll Down (J6 Pin 12)
Code