2 - 8
AC Power (J4 pins 1, 2, 3)
The MLP–Trim model #3200-1936
operates on 115 VAC + 15%, 0.1
Amp., 50/60 Hz. The MLP–Trim
model #3200-1937 operates on 230
VAC + 15%, 0.1 Amp., 50/60 Hz.
* Fuse L1 for 115VAC applica-
tions. Fuse L1 and L2 for
230VAC applications. Use
1 Amp 250V normal blow
fuses.
Lead Frequency (J6 pins 1, 3)
The Lead Frequency is a pulse train
input that the MLP–Trim uses to
determine the speed of the lead
motor. For signal level specifications,
refer to
References: Appendix A
,
MLP–Trim Specifications.
Figure 2-5 Input Power
Figure 2-6 Lead Frequency
L1
Neutral or L2
GND/PE
1
2
3
J4
*
*
Signal
Common
1
3
J6
Vista de pagina 23