Table 3-9 Entering Master Scaling Analog Feedback Parameters
CP Parameter Name Parameter Value
CP-84 Analog Input Allocation
CP-20 Master Engineering Units
Enter a value of "2" to allocate the
analog input as the feedback source.
Enter the Master Engineering Unit
value for an analog feedback level of
10.0 volts.
Note: The Max RPM Feedback (CP-34) and PPR Feedback (CP-31) control
parameters, used for scaling Master mode with frequency feedback, are
ignored when using analog feedback scaling.