2 - 10
Jog (J5 pins 5, 8)
Jog is a maintained input. When Jog
is closed, the MLP–Drive commands
the motor to move at the selected jog
speed. As a maintained input, Jog is
only active when the operator device
is closed.
NOTE: Close the R–Stop and
F–Stop inputs and open the
Run input, prior to entering
Jog. If you are only using
one of the Stop inputs, wire
short the other Stop input to
common or the MLP–Drive
will not enter Jog.
R–Stop (J5 pins 6, 8)
R–Stop is a momentary input. When
it is opened, the MLP–Drive ramps to
zero speed at the specified
deceleration rate. As a momentary
input, R–Stop is internally latched
and does not need to be maintained
by an operator device.
Figure 2-9 Jog
Figure 2-10 R–Stop