4 - 8
Output Test #5 - To Test the Logic Outputs
Press the “UP” or “DOWN” scroll keys until the diagnostic indicator and
the number “5” are visible on the left side of the LED display.
Only the diagnostic indicator and the number “5” will be visible on the
LED display during this test. To run this test, connect the outputs to a
pull up resistor and either a meter or LED, or connect the outputs to a
relay and either lights or sound.
Press “Enter” to start the test.
Press keys 1 - 2 to activate the outputs.
Press To Activate
1 Dig_Out1
2 Dig_Out2
Press “Clear” to exit the test.
Press “CODE SELECT” only if you want to exit diagnostics.