Contrex ML-Drive Manual de usuario Pagina 30

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 178
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 29
2 - 16
Figure 2-17 ML-Drive Serial Communications Connections
1. Shield only at one end of the cable.
2. If you need to terminate the communication line, then terminate
it at the unit which is the furthest away from the converter. A 100
ohm, 1/2 Watt resistor will usually terminate successfully. Refer
to EIA Standard RS485A, for more information.
Isolated
RS232 to RS485
Converter
2
1
ML-Drive #1
J1
T/R–
COM
T/R+
ML-Drive #2
1
2
3
J1
TXD/ TXD/
COM RXD RXD
— +
1
3
2
T/R–
COM
T/R+
Vista de pagina 29