C - 10
MP-58 SERIAL COMMUNICATIONS ERROR
Serial Communications Error (MP-58) identifies errors in the last transmitted message that was
sent to the ML-Drive by the host computer. The mode that displays a number “1” indicates the
error. In the example below, “Invalid Parameter Code” is the error.
Structure Error (Parity,Framing,No ETX, No STX)
Invalid Parameter Code
Invalid Parameter Data or Out of Data Min-Max Range
Control Mask Error
Code
MP-59 FREQUENCY OVERFLOW COUNTER
The Frequency Overflow Counter (MP-59) is a counter that increments each time the frequency
input to the ML-Drive causes an overflow. To reset the counter to “0”, press the Clear key.
CP-61 DIRECT ENABLE
In the Direct mode of operation, the drive output from the ML-Drive that is connected to the
motor can be set directly. Direct mode is an open-loop mode of operation. Use Direct Enable
(CP-61) to either enable or disable the Direct mode.
Enter "1" to enable the Direct Mode.
Enter “0” to disable the Direct Mode.
Enabled