2 - 12
Figure 2-13 Setpoint Select
Setpoint Select (J4 pins 13, 14)
The Master and Follower setpoints
are determined by the Setpoint Select
input combined with the Master,
Follower Input. For access to Master
Control Parameters 1 and 2 and
Follower Control Parameters 3 and 4,
refer to the chart below.
CONTROL
PARAMETER 1 OR 3
CONTROL
PARAMETER 2 OR 4
13
14
J4
Master, Follower
Input Open
Master, Follower
Input Closed
Setpoint Select / Closed Setpoint Select / Open
Master Control Parameter 1 Master Control Parameter 2
Follower Control Parameter 3
Follower Control Parameter 4