Contrex ML-Drive Manual de usuario Pagina 125

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 178
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 124
Glossary - 5
Drive Enable The Drive Enable output is activated based on the
Ramped Reference (MP-46) and the feedback. The
Ramped Reference is the calculated setpoint that is output
from the Acceleration/Deceleration routine.
See Appendix C; CP-74.
Engineering Units (E.U.) Master Engineering Units are the units of measure that
your system operates at, such as, RPMs, gallons per hour,
feet per minute. Follower Engineering Units is the number
that will represent the setpoint when the Lead and Follower
are operating at maximum capacity. Refer to Appendix C;
CP- 20 and CP-21.
EEPROM The EEPROM is where the default Control Parameters are
stored. This is not to be confused with the PROM chip
(which is the software for the ML-Drive).
F–Stop One of four operating states. F–Stop brings the
ML-Drive's drive output to an immediate Zero. F–Stop has
priority over the other operating states.
Follower Mode A complex multi-drive system. The scaling format allows
the operator to enter the setpoint as either a ratio or
percentage. The ML-Drive compares the setpoint ratio or
percentage to the Follower sensor shaft feedback and
Lead sensor shaft to calculate any speed error. When the
ML-Drive finds speed error, the control algorithm adjusts
the drive output and reduces the error to zero.
Gain See Appendix C;CP-65.
Hardwired Inputs that are wire shorted rather than using push buttons
or switches.