Contrex ML-TRIM Manual de usuario Pagina 76

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 180
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 75
3 - 42
Output Monitoring
These MPs monitor the ML–Trim's outputs.
MP-47 SPEED COMMAND OUT
The Speed Command Out (MP-47) displays the level of calibrated full scale analog
output to the motor drive (J2 pin 1). The Speed Command Out (MP 47) is displayed as
a percentage; 100 represents 100% of the calibrated full scale analog output.
MP-56 LOGIC OUTPUTS
The Logic Outputs (MP-56) displays the status of the Drive Enable and the Alarm digital
outputs. The number “1” indicates an inactive or de-energized (logic high) level. The
number “0” indicates an active or energized (logic low) level. In the example below,
“Alarm” is the inactive or de-energized (logic high) level.
Drive Enable (J5 Pin 16)
Alarm (J5 Pin 17)
Not Used
Not Used
Code