Contrex ML-TRIM Manual de usuario Pagina 70

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 180
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 69
3 - 36
Jog has the least operating priority. Jog ramps to the Jog Setpoint (CP-05), using the
Acceleration Time (CP-16). When Jog is terminated, the ML–Trim brings the Speed
Command output to an immediate Zero. Unlike the other inputs, Jog is not latched and
must be sustained to remain active.
To activate Jog:
Short the F–Stop and R–Stop inputs to common.
Open the Run input.
Short the Jog input to common. (Jog must be sustained to remain active).
R-STOP
F-STOP
RUN
JOG
COMMON
R-STOP
F-STOP
COMMON
JOG
RUN
Maintain Closed
6
7
8
9
10
11
J5
Vista de pagina 69
1 2 ... 65 66 67 68 69 70 71 72 73 74 75 ... 179 180