Contrex CX-1200 Manual de usuario Pagina 42

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 55
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 41
Page 40
Figure 2-42 Analog Input 1: Potentiometer Input
1
2
3
4
JA
+12V_Aux*
Common
+
-
Figure 2-43 Analog Input 2: Potentiometer Input
1
2
3
4
JA
+12V_Aux*
Common
+
-
Analog Input 1:
Potentiometer Input Wiring
(JA, Pins 1, 2, 4, 8)
The Analog Input 1 can be used with a potentiometer
(e.g., dancer pot). Figure 2-42 displays this option.
* The total current from JA pin 1 and J5 pin 1
(+12V_Aux) must not exceed 150 mA.
Analog Input 2:
Potentiometer Input Wiring
(JA, Pins 1, 5, 7, 8)
The Analog Input 1 can be used with a potentiometer
(e.g., dancer pot). Figure 2-43 displays this option.
* The total current from JA pin 1 and J5 pin 1
(+12V_Aux) must not exceed 150 mA