Page 38
Jog Reverse has nineth (the least) operating priority. Use UJogR to “Jog” the unwind drive Reverse or use
WJogR to “Jog” the wind drive Reverse at the rate indicated in Jog SP (CP-240). The acceleration and
deceleration ramps are dictated by Acl Tm Jog (CP-241), Dcl Tm Jog (CP-243) and Jog SP (CP-240). After
the UJogR or WJogR input is deactivated and the ramped reference has reached “0”, the CX-1102
automatically reverts to the F-Stop or H-Stop operating state.
To activate Jog Reverse:
Activate Low (closed to common), Level Sensitive, Not-Latched
Use momentary contact - needs to be maintained to remain active
Figure 38 Jog Reverse Input
UJogF
UJogR
Commo
n
F-Stp
UnLd
H-Stp
Run
Commo
n
Jog Fwd
Close Maintained
J7
1
2
3
1
2
4
6
3
J6
H-Stop
Run
Unload
Jog Rvs
F-Stop