Page 37
Figure 37 Jog Forward Input
UJogF
Commo
n
F-Stp
UnLd
H-Stp
Run
Commo
n
Jog Fwd
Run
Close Maintained
J7
1
3
1
2
4
6
3
J6
H-Stop
Unload
F-Stop
Jog Forward has the eighth highest operating priority. Use UJogF to “Jog” the unwind drive Forward or use
WJogF to “Jog” the wind drive Forward at the rate indicated in Jog SP (CP-240). The acceleration and
deceleration ramps are dictated by Acl Tm Jog (CP-241), Dcl Tm Jog (CP-243) and Jog SP (CP-240). After
the UJogF or WJogF input is deactivated and the ramped reference has reached “0”, the CX-1102
automatically reverts to the F-Stop or H-Stop operating state.
To activate Jog Forward:
Activate Low (closed to common), Level Sensitive, Not-Latched