Page 17
Keypad Lockout
(J7 pins 8, 9)
Digital Input 6
When the KEYPAD LOCKOUT input is closed, the
Control Parameters that you have selected to "lock out"
are inaccessible from the front keypad. All of the
Monitor Parameters remain enabled.
Block Select A
(J7 pins 1, 3)
Digital Input 8
Use BLOCK SELECT A in conjunction with BLOCK
SELECT B and BLOCK SELECT C inputs to select one
of the eight Parameter Blocks. Refer to the chart on
the next page.
Block Select B
(J7 pins 2,3)
Digital Input 9
Use BLOCK SELECT B in conjunction with BLOCK
SELECT A and BLOCK SELECT C inputs to select one
of the eight Parameter Blocks. Refer to the chart
below.
Figure 19 Keypad Lockout
ENABLE
8
9
J7
LOCKOUT
COM
DI_6
Figure 20 Block Select A
BLOCK
SELECT A
1
3
J7
DI_8
COM
Figure 21 Block Select B
BLOCK
SELECT B
2
3
J7
DI_9
COM